Separate Published Modes From the Intended Use
The DEPPLUS page lists fractional, cutting, and vaginal operating modes as product features. Those labels do not establish which uses, accessories, operator qualifications, or documents apply in every destination market. Describe the planned professional setting and service category, then request the configuration and documentation that apply to that specific use before treating a listed mode as part of the purchase decision.
The published 10,600 nm wavelength and 15–70 W range should remain tied to the quoted DEPPLUS system. Confirm the tube configuration, scanner, included accessories, aiming beam, cooling arrangement, and software or scan modes on the same current specification sheet.
Use the Scan Controls to Structure the Demonstration
The legacy specification lists a maximum scan scope of 20 × 20 mm, adjustable duration, adjustable distance, interval settings, and repeat values. Ask the supplier to demonstrate how the quoted interface presents these controls and which accessories are used with each operating mode. The goal is to understand the supplied workflow, not to infer a treatment result from the existence of an adjustable setting.
Record the exact control ranges shown for the delivered configuration and the version of the operating material used during training. If a distributor will support several clinic customers, agree on how interface, scanner, accessory, and document questions will be escalated after delivery.
Confirm Installation and Ownership Details
DEPPLUS is presented as a stationary platform with published size and weight information. Confirm the packed dimensions, delivery access, electrical requirement, cooling needs, treatment-room placement, and receiving procedure. Ask who will inspect the shipment, attend training, store the equipment record, and contact technical support when a question arises.
Before ordering, obtain the current specification, accessory list, packing information, training plan, warranty terms, maintenance route, and market-specific documents in writing. The legacy page contains a wavelength typo outside its specification table, so every critical value should be checked against the current signed record rather than copied from surrounding marketing text.
Ask the quotation to separate the base system, scanner, tube option, treatment accessories, training items, and any market-specific documentation. A line-by-line inclusion record helps a clinic or distributor compare the offered configuration without assuming that every published mode is supplied by default.